LL_ADC_REG_SetTriggerSource() function

Set ADC group regular conversion trigger source: internal (SW start) or from external IP (timer event, external interrupt line).

Syntax

__STATIC_INLINE void LL_ADC_REG_SetTriggerSource(ADC_TypeDef *ADCx,     uint32_t TriggerSource);

Arguments

Return value

None

Notes

On this STM32 series, setting of external trigger edge is performed using function LL_ADC_REG_StartConversionExtTrig(). Availability of parameters of trigger sources from timer depends on timers availability on the selected device. CR2 EXTEN LL_ADC_REG_SetTriggerSource

Examples

LL_ADC_REG_SetTriggerSource() is referenced by 9 libraries and example projects.

References

LocationReferrerText
stm32f4xx_ll_adc.h:2149
__STATIC_INLINE void LL_ADC_REG_SetTriggerSource(ADC_TypeDef *ADCx, uint32_t TriggerSource)
stm32f4xx_ll_adc.c:439LL_ADC_DeInit()
LL_ADC_REG_SetTriggerSource(ADCx, LL_ADC_REG_TRIG_SOFTWARE);