ConversionStartPoll_ADC_GrpRegular() is only used within ADC_ContinuousConversion_TriggerSW_Init.
 
Symbols
loading...
Files
loading...

ConversionStartPoll_ADC_GrpRegular() function

Perform ADC group regular conversion start, poll for conversion completion. (ADC instance: ADC1).

Syntax

void ConversionStartPoll_ADC_GrpRegular(void);
Implemented in main.c:528

Return value

None

Notes

This function does not perform ADC group regular conversion stop: intended to be used with ADC in single mode, trigger SW start (only 1 ADC conversion done at each trigger, no conversion stop needed). In case of continuous mode or conversion trigger set to external trigger, ADC group regular conversion stop must be added.

References

LocationReferrerText
main.c:528
void ConversionStartPoll_ADC_GrpRegular(void)
main.c:101
void ConversionStartPoll_ADC_GrpRegular(void);
main.c:167main()
ConversionStartPoll_ADC_GrpRegular();

Call Tree

Functions calling ConversionStartPoll_ADC_GrpRegular()
Functions called by ConversionStartPoll_ADC_GrpRegular()
all items filtered out
ConversionStartPoll_ADC_GrpRegular()